Short answer. The ring that turns relative to the load needs an interference fit. The ring that stays still relative to the load can have a loose fit. In most machines the shaft turns and the load direction is fixed, so the inner ring goes tight on the shaft and the outer ring goes loose in the housing.
Then choose how tight from the load size and the shaft diameter. Check how much internal clearance the fit will remove. A correct tolerance class with the wrong clearance can still run hot.
Why the fit matters
Too loose. The ring creeps, which means it slowly turns on its seat. Bolting or clamping the ring faces does not always stop this. The seat wears, metal particles can enter the bearing, and heat and vibration follow [1].
Too tight. The fit removes internal clearance and raises the stress in the ring. The bearing runs hot and noisy, and life falls. An extreme fit can crack a ring [1].
Step 1: decide which ring needs the tight fit
| What rotates | Load direction | Load on inner ring | Inner ring fit | Outer ring fit |
|---|---|---|---|---|
| Shaft (inner ring) | Fixed, such as gravity or belt pull | Rotating | Tight | Loose |
| Housing (outer ring) | Fixed | Stationary | Loose | Tight |
| Shaft | Load turns with the shaft, such as an unbalance | Stationary | Loose | Tight |
| Varies | Direction changes or cannot be predicted | Indeterminate | Tight | Tight |
The third row catches people out. The shaft is turning, yet a heavy unbalance turning with it puts the rotating load on the outer ring.
Oscillating loads count as rotating loads when you select a fit [2].
Step 2: classify the load
Compare the equivalent load P with the dynamic load rating C:
| Load class for ball bearings | P/C |
|---|---|
| Light or variable | Below 0.05 |
| Normal | 0.05 to 0.12 |
| Heavy | Above 0.12 |
A 6204 with C = 12,800 N and P = 1,000 N has P/C of about 0.08, which is a normal load. To calculate P, see bearing load ratings and L10 life.
Step 3: choose the shaft tolerance
For radial ball bearings of normal and class 6 precision on a solid steel shaft:
| Load condition | Shaft diameter (mm) | Shaft tolerance |
|---|---|---|
| Outer ring rotating load, inner ring must slide easily | All | g6 |
| Outer ring rotating load, inner ring need not slide | All | h6 |
| Inner ring rotating, light load | Below 18 | js5 |
| Inner ring rotating, light load | 18 to 100 | js6 (j6) |
| Inner ring rotating, light load | 100 to 200 | k6 |
| Inner ring rotating, normal load | Below 18 | js5 or js6 (j5 or j6) |
| Inner ring rotating, normal load | 18 to 100 | k5 or k6 |
| Inner ring rotating, normal load | 100 to 140 | m5 or m6 |
| Inner ring rotating, heavy load | 50 to 140 | n6, with clearance above CN |
Electric motors with deep groove ball bearings have their own common recommendation:
| Bore (mm) | Shaft | Housing |
|---|---|---|
| 10 to 18 | js5 (j5) | H6 or H7 if the outer ring must move axially; JS6 or JS7 (J6 or J7) if it need not |
| 18 to 100 | k5 | Same |
| 100 to 160 | m5 | Same |
Use the 5-grade class where accuracy matters, because the tolerance band is narrower. High-precision ball bearings with a bore of 18 mm or less use h5 [1].
Step 4: choose the housing tolerance
For cast iron or steel housings:
| Load condition | Requirement | Housing tolerance | Can the outer ring move axially? |
|---|---|---|---|
| Inner ring rotating, any load | General use | H7 | Yes, easily |
| Inner ring rotating, light or normal load | Less demanding | H8 | Yes, easily |
| Inner ring rotating, shaft heats the bearing | Hot shaft | G7 | Yes, easily |
| Inner ring rotating | Lowest noise | H6 | Yes, easily |
| Light or normal load | Accurate running | JS6 (J6) | Possible |
| Indeterminate direction, light or normal | General use | JS7 (J7) | Possible |
| Indeterminate direction, normal or heavy | General use | K7 | Generally not |
| Outer ring rotating, light or variable | Tension pulleys | M7 | No |
| Outer ring rotating, normal or heavy | Ball bearing wheel hubs | N7 | No |
| Outer ring rotating, heavy, thin housing | Heavy shock | P7 | No |
A floating bearing must slide in its seat as the shaft grows with heat. Choose a housing class that allows it.
When the standard table needs adjusting
- Hollow shaft or thin-walled housing. Tighter than the table. The wall deforms and the fit loosens [2].
- Light-alloy housing. Tighter than the table. Aluminium grows more than bearing steel with heat, so the outer ring can loosen when hot [1].
- Stainless steel shaft. A lighter fit such as j5 or h5 may be needed when the temperature difference between the rings is large [4].
- Hot inner ring. Heat loosens the inner ring fit and takes up clearance at the same time. Check both.
- Rapid start-up. Frictional heat can loosen the inner ring fit before it spreads into the shaft [2].
Worked example: what the fit really does on a 6204
A 6204 has d = 20 mm and D = 47 mm. At normal precision the bore tolerance is 0/−10 μm and the outside diameter tolerance is 0/−11 μm.
| Seat | Limits (μm) | Result on the fit |
|---|---|---|
| Shaft h5 | 0 / −9 | 9 clearance to 10 interference |
| Shaft js5 | +4.5 / −4.5 | 4.5 clearance to 14.5 interference |
| Shaft k5 | +11 / +2 | 2 to 21 interference |
| Shaft k6 | +15 / +2 | 2 to 25 interference |
| Shaft m5 | +17 / +8 | 8 to 27 interference |
| Housing H7 | +25 / 0 | 0 to 36 clearance |
| Housing H6 | +16 / 0 | 0 to 27 clearance |
| Housing JS7 | +12.5 / −12.5 | 23.5 clearance to 12.5 interference |
Bearing tolerances are biased towards the minus side. This is why k5 gives interference across its whole range, even though the shaft tolerance looks small.
A fit uses up clearance
Interference expands the inner ring. About 70% to 90% of the effective interference becomes lost radial clearance [1]. Effective interference is slightly less than the measured value, because the fit flattens surface roughness [1].
Take the 6204 on a k5 shaft, with a bearing of CN clearance (5 to 20 μm):
| Case | Interference | Effective | Clearance lost |
|---|---|---|---|
| Middle of the tolerance | 11.5 μm | about 10.5 μm | about 7 to 9 μm |
| Tightest case | 21 μm | about 19 μm | about 13 to 17 μm |
So a tight shaft on a low-clearance CN bearing can reach zero or below, before the inner ring heats up. This does not happen on every bearing, because the tightest case is rare. It does explain why a small share of a batch can run hot while the rest are fine.
That is why published guidance notes that normally to heavily loaded ball bearings often need more than normal clearance with these shaft tolerances [3]. See C2, CN, C3 and C4 explained.
Other losses are usually small on small bearings
| Effect | Formula from [1] | 6204 result |
|---|---|---|
| Interference lost under radial load | Δd = 0.08 × √(d/B × Fr) × 10⁻³ mm | About 3 μm at 1,000 N |
| Interference lost when the bearing runs hotter than the housing | Δd ≈ 0.0015 × ΔT × d × 10⁻³ mm | About 0.6 μm at ΔT = 20 °C |
For small bearings, the tolerance band is a far bigger variable than these two effects. On large, heavily loaded bearings they matter more.
Seat quality matters as much as the tolerance class
A good fit on a poor seat still distorts the raceway.
| Item (normal and class 6 bearings) | Shaft | Housing bore |
|---|---|---|
| Out-of-roundness | IT3/2 to IT4/2 | IT4/2 to IT5/2 |
| Cylindricity | IT3/2 to IT4/2 | IT4/2 to IT5/2 |
| Shoulder runout | IT3 | IT3 to IT4 |
| Roughness Ra, small bearings | 0.8 μm | 1.6 μm |
| Roughness Ra, large bearings | 1.6 μm | 3.2 μm |
For our 6204, out-of-roundness works out to about 2 to 3 μm on the shaft and about 3.5 to 5.5 μm in the housing. Low-noise and high-precision bearings need tighter seats still, because the ring follows the shape of the seat. See raceway roundness and bearing noise.
The fillet on the shaft or housing must be smaller than the bearing chamfer. If it is not, the ring will sit on the fillet and will not seat against the shoulder.
Symptoms of a wrong fit
| What you see | Likely fit problem | What to check first |
|---|---|---|
| Polished or worn bearing seat, ring turns by hand | Too loose, creep | Load direction, seat diameter |
| Dark marks or fretting rust on the bore or outside diameter | Micro-movement in a loose fit | Seat tolerance, vibration |
| Hot soon after start-up | Too tight, or clearance too small | Actual interference, clearance class |
| Noise only after pressing in | Ring distortion or mounting damage | Seat roundness, press method |
| Floating bearing cannot slide, heat rises with time | Outer ring too tight | Housing tolerance, thermal growth |
| Some bearings in a batch run hot | Tolerance stack at the tight end | Measure shafts and matching bearings |
Measure before changing the design. Use a real shaft and housing, and record the diameter at more than one position. For more, see new bearing noisy or hot after installation and why bearings overheat.
Use the calculator
The fit and tolerance calculator gives a recommended fit by bore and operating condition. It also shows the interference, the clearance and the radial clearance the fit removes, for 5-grade and 6-grade shaft classes.
What to tell us when you ask about a fit
- Bearing number and clearance class
- Which part rotates, and the load direction
- Load and speed
- Shaft material, and whether it is solid or hollow
- Housing material and wall thickness
- Temperature of the shaft and of the housing
- Your drawing tolerances, or measured seat sizes
Frequently asked questions
What is the most common fit for a deep groove ball bearing in a motor? For a motor with a rotating shaft, published guidance gives k5 on the shaft for bores from above 18 mm to 100 mm, js5 for smaller bores, and H6 or H7 in the housing when the outer ring needs to slide.
Can I glue a bearing in place of an interference fit? Adhesive is used in some small assemblies, but it does not change the rules on load direction or clearance. Validate it on your own parts, because a fit that relies only on adhesive depends on the process.
Should both rings have an interference fit? Only when the load direction is indeterminate or both rings carry a rotating load. Remember that both fits take up clearance, and mounting is harder.
Does a tighter fit always stop creep? It helps, up to a point. If the load is very high or the seat is soft, thin or hollow, check those first. Too much interference brings its own heat and stress problems.
Why do you list k5 when many drawings say k6? Both can be correct for a normal load from 18 to 100 mm. k5 has a narrower band, so the interference and the clearance loss vary less. k6 is easier to machine. Choose based on your precision and noise needs.
Sources and data boundary
The recommendations below are published guidance for solid steel shafts and cast iron or steel housings. They are a starting point. Confirm with a calculation and with tests on your own parts. Worked examples are our own calculations.
- NSK. Rolling Bearings catalogue E1103, sections 8 and 13: fits, internal clearances, shaft and housing design.
- SKF. Selecting fits. www.skf.com
- SKF. Pulp & Paper Practices, Table 1: fits for solid steel shafts. cdn.skfmediahub.skf.com
- SKF. The SKF pump bearing. www.skf.com
- ISO 286 limits and fits; ISO 492 radial bearing tolerances.
Related guides
- Bearing load ratings and L10 life
- Bearing clearance: C2, CN, C3 and C4
- Bearing precision grades
- Starting and running torque
Ningbo Shuanghua Bearing (NLHB) is a bearing factory in Cixi, China. Send your bearing number, shaft and housing tolerances and operating conditions, and we will check the fit and clearance with you: request a quote.